You asked: When two firefighters are operating a small Hoseline the backup firefighter should be positioned?

When two firefighters are operating a small hoseline, the backup firefighter should be positioned: c. on the same side of the hose as the nozzle firefighter. What is the purpose of a standpipe?

When operating hose off a ladder How should firefighters be positioned?

When advancing a dry line to the point of operation, it is recommended that a firefighter carry the nozzle by: placing the hose over the shoulder with the nozzle in front, resting on the chest. One-inch rubber-covered and rubber-lined hose equipped with one-inch couplings is commonly called a: booster hose.

How can friction loss be overcome or reduced?

Solutions for Friction Loss

  1. Reduce interior surface roughness of the piping system.
  2. Increase pipe diameter of the piping system.
  3. Minimize length of piping system.
  4. Minimize the number of elbows, tees, valves, fittings, and other obstructions in the piping system; replace 90 degree turns with gentle bends.

Which describes a master stream device?

A master stream is a fire service term for a water stream of 350 US gallons (1,300 liters) per minute or greater. It is delivered by a master stream device, such as a deck gun, deluge gun, or fire monitor. Master streams are often found at the end of aerial ladders, tele-squirt nozzles, or monitor nozzles.

IT IS IMPORTANT:  Quick Answer: Who is responsible for inspecting fire extinguishers?

What is one advantage of a Minuteman load?

One final advantage with the minute-man load is the ability to easily extend a line by shouldering the nozzle bundle, disconnecting it from the supply bundle, then adding it to the end of your line for an additional 100-feet of attack line.

When using elevators fire fighters should stop?

You should keep a firefighter with the car or place a tool, such as a halligan or hook in the path of the door in case the hold feature fails. ∞ On the way up you should stop the elevator car to check the stop feature. When the car stops, open the door and shine a light up the shaft to check for any smoke or water.

What is a hard suction hose most commonly used for?

Hard Suction Hose is used to suck water out of unpressurized sources, such a ponds or rivers, by means of a vacuum. Available in lengths of up to 50 ft.

What is the friction loss in a fire hose?

Friction loss is the resulting resistance as water (fluid) moves along the inside wall of either a hose, pipe, or hose fittings. Points to remember about friction loss: Friction loss increases as flow (gpm) increases.

How many firefighters does it take to deploy a master stream?

Fortunately, it only takes one firefighter to operate a master stream, so while it’s being operated, another firefighter can start deploying a 2½” line.

What pressure do you pump a master stream?

Master Stream Devices: Nozzle Pressure + 10 PSI for the device. Older devices with multiple intakes and stream straightener Nozzle Pressure + 20 PSI.

IT IS IMPORTANT:  Best answer: What is a California campfire permit?

What does the E stand for in the acronym Slice RS?

It stands for Size-up, Locate the fire, Isolate the flow path, Cool from a safe distance, Extinguish, Rescue and Salvage at any time in the process. It updates a previous acronym used by firefighting departments: RECEO-VS, which stands for Rescue, Exposure, Confine, Extinguish, Overhaul and Ventilate, Salvage.