Frequent question: Is specification of fire extinguisher?

Is specification for fire extinguisher?

The details in regard to the maintenance are given in IS 2190 : 1992 ‘Code of practice for selection, installation and maintenance of portable first aid fire extinguishers ( third revision )’. This standard was first published in 1962 and revised in 1972, 1976 and 1985.

What is a fire extinguisher classified as?

Fire extinguishers are classified by the type of fire that they will extinguish. A Class A fire extinguisher is used for ordinary combustibles, such as wood, paper, some plastics, and textiles.

The ABCs, Ds, and Ks of Fire Extinguishers.

Fire Class Travel Distance
Class C Based on appropriate A or B Hazard
Class D 75 feet

What is the OSHA standard for fire extinguishers?

NFPA recommends one 2-A fire extinguisher for every 3,000 square feet. OSHA requires employees to have access to an extinguisher within 75 feet. Employees should have access to a fire extinguisher within either 30 or 50 feet, depending on the hazard in question and the rating of the extinguisher (see below).

Does fire extinguisher expire?

Even if there’s no expiration date, it won’t last forever. Manufacturers say most extinguishers should work for 5 to 15 years, but you might not know if you got yours three years ago or 13. … If it falls anywhere else, the extinguisher is unreliable and should be serviced or replaced.

IT IS IMPORTANT:  Can you use an elevator after the fire alarm system has been activated?

What are the 4 types of fire extinguishers?

There are four classes of fire extinguishers – A, B, C and D – and each class can put out a different type of fire. Multipurpose extinguishers can be used on different types of fires and will be labeled with more than one class, like A-B, B-C or A-B-C.

What are the 5 classes of fire extinguishers?

What are the 5 Types of Fire Extinguishers?

  • Class A Fire Extinguishers. Class A fire extinguishers are safe for use on ordinary combustible fires, like those fueled by paper or wood. …
  • Class B Fire Extinguishers. …
  • Class C Fire Extinguishers. …
  • Class D Fire Extinguishers. …
  • Class K Fire Extinguishers.

Where should I place fire extinguishers?

The extinguishers should be placed in areas that are accessible within seconds. Place them in easy-to-grab spots, near exits. The National Fire Protection Association recommends having at least one fire extinguisher on every floor of the home. The first location should be the kitchen.

How do you calculate the number of fire extinguishers?

The calculation can be simplified by applying the rule of thumb that one 13A extinguisher covers 200 square metres of floor area. To calculate how many 13A extinguishers are required, divide the floor area by 200, and round up.